Beam Section Holder TPH F 100
Application
Interface element to connect 90° intersecting Beam Sections F100. Alternatively the Beam Section Holder TPH may be used to connect only one beam section to an even surface with suitable wall anchors or with cast-in channel accessories.
Installation
Connecting one Beam Section F100 90° to another one by using 6 x Self Forming Screw FLS applied through all elongated holes. Connecting to any other surface or member by using 2 x Self Forming Screws FLS through the two elongated holes on the top of the Beam Section Holder TPH F100 plus 2 appropriate fixing elements up to M12 through the two holes “d1”.
Technical Data
Type | L x b x s [in] | ø d1 [in] | Elongated slot LL(1) d x a [in] | Elongated slot LL(2) d x a [in] |
---|---|---|---|---|
TPH F 100 C | 8 5/8" x 3 15/16" x 1/6" | 9/16" | 7/16" x 13/16" | 7/16" x 13/16" |
TPH F 100/80 C | 7 13/16" x 3 15/16" x 1/6" | 9/16" | 7/16" x 13/16" | 7/16" x 13/16" |
Type | L x b x s [mm] | ø d1 [mm] | Elongated hole LL1 d x a [mm] | Elongated hole LL2 d x a [mm] |
---|---|---|---|---|
TPH F 100 C | 219 x 100 x 4 | 14 | 11 x 20 | 11 x 20 |
TPH F 100/80 C | 199 x 100 x 4 | 14 | 11 x 20 | 11 x 20 |
Typ | Fx [kN] | Fy [kN] | Fz [kN] | My [kNm] | Mz [kNm] |
---|---|---|---|---|---|
TPH F 100 C | 6,2 | 12,7 | 12,3 | 0,6 | 0,5 |
TPH F 100/80 C | 6,2 | 12,7 | 12,3 | 0,6 | 0,5 |
The above load data indicates permissible loads and includes Partial Safety Factors γM2 = 1.25 (EN 1993-1-8:2010-12,
Tab. 2.1) and γG = 1.35 (EN 1990:2010-12, Tab. A1.2(B)) for general permanent actions.
Material: | Steel, HCP |